JavaScript is disabled for your browser. Some features of this site may not work without it.

    Listar

    Todo RIUMAComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasTipo de publicaciónCentrosDepartamentos/InstitutosEditoresEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasTipo de publicaciónCentrosDepartamentos/InstitutosEditores

    Mi cuenta

    AccederRegistro

    Estadísticas

    Ver Estadísticas de uso

    DE INTERÉS

    Datos de investigaciónReglamento de ciencia abierta de la UMAPolítica de RIUMAPolitica de datos de investigación en RIUMAOpen Policy Finder (antes Sherpa-Romeo)Dulcinea
    Preguntas frecuentesManual de usoContacto/Sugerencias
    Ver ítem 
    •   RIUMA Principal
    • Investigación
    • Ponencias, Comunicaciones a congresos y Pósteres
    • Ver ítem
    •   RIUMA Principal
    • Investigación
    • Ponencias, Comunicaciones a congresos y Pósteres
    • Ver ítem

    Validity and reliability of range of motion measured on smartphone (mROM)

    • Autor
      Cuesta-Vargas, AntonioAutoridad Universidad de Málaga
    • Fecha
      2014-10-16
    • Palabras clave
      Fisioterapia - Innovaciones tecnológicas
    • Resumen
      Background: Nowadays, as internet-based communication is advancing rapidly, it is getting more and more interesting to adapt clinical examination of patients to remote communication. The use of smartphone photographic is presented as a method for studying the measurement of shoulders joint ROM. Objective: To investigate the reliability of smartphone photographic measurements of upper limbs abduction angle through mRom app compared to inertial sensors as the criterion standard. Methods: This cross-sectional involved 28 subjects: 14 healthy persons and 14 persons suffering from shoulder pathology. Descriptive and anthropometric independent variables were included. A physical property was included corresponding to a dependent variable: mobility angle (degrees), which was obtained thought two different devices. On the one hand, as criterion standard, the inertial measurement sensors with two inertial sensors (InertiaCube3™ Intersense Inc., Billerica, Massachusetts) located in the middle third of the humerus slightly posterior and in the flat part of the sternum. It contains an inertial 3 Degree of Freedom orientation tracking system: yaw, pitch, and roll. On the other hand, degrees were also obtained using a smartphone Nexus 4 (LG Electronics INC, Yeouido-dong, Seoul) with an 8 megapixels main camera and a 4.7 inches Corning Gorilla Glass 2 touchscreen. The app used was mROM Lite (Brain Dynamics SL, Málaga, Spain), available in google store. Three photographs were taken by two examiners from 3 independents set of images, and they were taken at the same time as inertial measurement. Participants were placed standing, starting from neutral position, performing shoulder abduction. Results: The mean ± SD age of the healthy participants (8 female, 6 male) was 56.1 ± 9.1 years, and their body mass index (BMI) was 27.12 ± 3.8 Kg/m2. The mean ± SD age of the participants with shoulder pathology (8 female, 6 male) was 54.4 ± 10 years and their average BMI was 28± 6.7 Kg/m2. Intraclass correlation coefficients ICC(2-1) for intrarrater reliability for inertial measurements taken by the first examiner was 0.993 (95%CI: 0.983, 0.998) for subject with pathological shoulders, 0.982 (95%CI: 0.736, 0.962) for healthy subjects and 0.992 (95%CI: 0.984, 0.996) for the total sample. Values for photographic measurements were 0.865 (95%CI: 0.670, 0.953) for healthy subjects, 0.991 (95%CI: 0.977, 0.997) for subjects suffering from shoulder pathology and 0.996 (95%CI: 0.992, 0.998) for the total sample. The ICC(2-1) for measurements taken by two different examiners was 0.711 (95%CI: 0.099, 0.907) for the first photograph, 0.703 (95% CI: 0.076, 0.905) for the second one and 0.892 (95%CI: 0.663, 0.965) for the third one in healthy subject. In subject with pathology it was 0.994 (95% CI: 0.982, 0.998), 0.998 (95% CI: 0.993, 0.999) and 0.996 (95% CI: 0.989, 0.999) respectively. In the total sample it was 0.997 (95%CI: 0.992, 0.998), 0.998 (95%CI: 0.995, 0.999) and 0.998 (95%CI: 0.995, 0.999) respectively. Conclusions: Smartphone photographic measurements of upper limbs abduction angle through mRom app are reliable compared to inertial sensors. This method provides a convenient and precise tool in assessment of shoulder motion.
    • URI
      http://hdl.handle.net/10630/8251
    • Compartir
      RefworksMendeley
    Mostrar el registro completo del ítem
    Ficheros
    Validity and Reliability of Range of Motion Measured on Smartphone (mROM).pdf (38.55Kb)
    Colecciones
    • Ponencias, Comunicaciones a congresos y Pósteres

    Estadísticas

    Buscar en Dimension
    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA
    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA
     

     

    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA
    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA