Mostrando ítems 1-20 de 36
-
A comparison of heating terminal units: Fan-coil versus radiant floor, and the combination of both
Atienza-Márquez, Antonio; Fernández-Hernández, Francisco Ángel; Domínguez-Muñoz, Fernando
; Carrillo-Andrés, Antonio
; Cejudo-López, José Manuel
(Elsevier, 2017)
Several control strategies are compared for a hydronic heating system that combines two different terminal units, radiant floor and fan-coil, in the same thermal zone. The performance of the combined system is evaluated ... -
A decision-making LCA for energy refurbishment of buildings: Conditions of comfort
Assiego-de-Larriva, Rafael; Calleja Rodríguez, Gloria; Cejudo-López, José Manuel
; Raugei, Marco; Fullana i Palmer, Pere (Elsevier, 2014)
This paper is focused on providing information to help in decision-making between five different scenarios for energy refurbishment, evaluating the lifecycle of each and also taking into consideration the level of comfort ... -
An experimental and numerical model of a desiccant façade. A case of study of an office building in different weather conditions
Fernández-Hernández, Francisco Ángel; Jiménez-Navarro, Juan Pablo; Atienza-Márquez, Antonio; Cejudo-López, José Manuel
; Carillo-Andrés, Antonio (Elsevier, 2020-10-01)
Meeting thermal comfort in buildings with high latent loads requires the treatment of the air humidity with specific technologies. Desiccant based systems have proved to be effective in removing ventilation latent load in ... -
Análisis del efecto del caudal del primario en instalaciones solares térmicas para producción de ACS
Plaza-Gomáriz, Francisco de Asís (UMA Editorial, 2019-12-18)Esta tesis es el resultado de 5 años de investigación sobre la importancia que tiene el caudal de circulación de fluido en el circuito primario de una instalación solar térmica, y ha combinado trabajo experimental en banco ... -
Analysis of the thermal performance of heat exchangers for active chilled beam units
Domínguez-Muñoz, Fernando; González Espín, José Luis; Coronas Salcedo, Alberto; Cejudo-López, José Manuel
(2018-06-28)
Coils used in active chilled beams (ACB) have some distinctive features compared to conventional coils used in fan-coil units. On the air side, the flow rate of induced air is limited and air velocities are thus much lower ... -
Caracterización térmica y evaluación de diversas estrategias de control de condensación de vigas frías activas
González Espín, José Luis; Coronas Salcedo, Alberto; Cejudo-López, José Manuel; Domínguez-Muñoz, Fernando
(Instituto de Ingeniería Energética. Universidad Politécnica de Valencia, 2018-06)
La aparición de condensación en la batería de intercambio de calor es uno de los principales problemas a evitar en una viga fría activa (VFA). En climas húmedos, por las infiltraciones de aire exterior, y en espacios de ... -
Design under uncertainty of solar hot water systems for hospitals
Atienza Márquez, Antonio; Domínguez-Muñoz, Fernando; Fernández-Hernández, Francisco Ángel
; Cejudo-López, José Manuel
(2022)
Failed designs are often behind underperforming solar hot water systems and excessive fossil fuel consumption in backup units. This paper proposed a reliable and robust method to design a solar thermal system combined with ... -
Detailed and simplified models of a terminal unit that combines an UFAD system with a floor cooling
Atienza-Márquez, Antonio; Fernández-Hernández, Francisco Ángel; Domínguez-Muñoz, Fernando
; Cejudo-López, José Manuel
(Elsevier, 2018)
This paper analyses the thermal behaviour of an underfloor air distribution system (UFAD) combined with a floor cooling, focusing on the thermal decay (TD). Two new models were implemented: a detailed model based on the ... -
Diseño de un pabellón semiabierto para usos docentes en el Campus de Teatinos (Málaga)
Domínguez-Muñoz, Fernando; Ortega-Casanova, Joaquín
; Cejudo-López, José Manuel
; Gavilanes-Velaz-de-Medrano, Juan
; Ventura-Blanch, Ferrán
(2020-11-17)
Los espacios exteriores raramente se utilizan para desarrollar actividades docentes, ya que resulta difícil asegurar las condiciones requeridas de confort térmico, lumínico y acústico. Estos problemas pueden mitigarse en ... -
Domestic hot water production system in a hospital: Energy audit and evaluation of measures to boost the solar contribution
Atienza Márquez, Antonio; Domínguez-Muñoz, Fernando; Fernández-Hernández, Francisco Ángel
; Cejudo-López, José Manuel
(Elsevier, 2022-12-15)
Hospitals consume large quantities of energy to produce hot water and offset the distribution and recirculation thermal losses. This paper analyses a solar thermal system combined with gas boilers for domestic hot water ... -
EFFECTS OF LOUVERS SHADING DEVICES ON VISUAL COMFORT AND ENERGY DEMAND OF AN OFFICE BUILDING. A CASE OF STUDY
Fernández-Hernández, Francisco Ángel; Cejudo-López, José Manuel
; Peña Suárez, José Miguel; González Murriano, Mª Carmen; Carrillo Rueda, Simón (2017-05-16)
This paper evaluates the building energy demand and visual comfort of a real case with a glazed façade office building placed in Málaga (Mediterranean city in the south of Spain). South oriented facades receive such a ... -
Eficiencia energética en edificios desde la perspectiva de ciclo de vida. Casos de estudio
Assiego-de-Larriva, Rafael(Servicio de Publicaciones y Divulgación Científica, 2015)
De un lado, en esta Tesis, se establecen unos avances que permiten la integración de los parámetros que definen la eficiencia energética de un edificio en las distintas fases de un ACV. Por otro lado, la incorporación de ... -
Energyplus simulation model of a zoning regulation system intgegrated with an unitary ducted air-to-air heat pump
Fernández-Hernández, Francisco Ángel; Peña Suárez, José Miguel; Carrillo-Andrés, Antonio
; Sojo-Gordillo, José Manuel; Guarino Molina, Samuel; Cejudo-López, José Manuel
; Domínguez-Muñoz, Fernando
[et al.] (Instituto de Ingeniería Energética. Universidad Politécnica de Valencia, 2018-06)
En los edificios se pueden distinguir una variedad de zonas con diferentes patrones de utilización y perfiles de cargas térmicas. Los sistemas de climatización zonificados permiten adaptarse a las diferentes demandas ... -
Estudio experimental de una nueva terminal: integración de un suelo radiante en un sistema de ventilación por plenum
Fernández-Hernández, Francisco Ángel; Cejudo-López, José Manuel
; Fernández-Gutiérrez, Alberto
; Carrillo-Andrés, Antonio
; Domínguez-Muñoz, Fernando
(Celestino Ruivo y Adelio Gaspar, 2016)
En este trabajo se describe la nueva unidad terminal y se realiza un análisis experimental de la misma. Se han llevado a cabo ensayos del sistema en un suelo de 3x3 m2, para unas condiciones de verano. Se describe el montaje ... -
Estudio experimental y numérico del comportamiento de un modelo de difusor de aire por desplazamiento acoplado a un suelo frío
Fernández-Gutiérrez, Alberto; Parras-Anguita, Luis
; González Prieto, Ignacio; Del-Pino-Peñas, Carlos Manuel
; Cejudo-López, José Manuel
(2013-07-10)
En la última década se han realizado muchos trabajos sobre sistemas de refrigeración para grandes superficies usando ventilación por desplazamiento con suelos radiantes (por ejemplo en aeropuertos y estaciones). De especial ... -
Evaluación energética comparativa del ciclo de vida en viviendas sociales y propuesta de optimización para clima cálido de Argentina.
Molas Gazquez, Lucio Augusto (UMA Editorial, 2024)Los edificios causan un impacto ambiental al consumir energía en los procesos unitarios del ciclo de vida, desde la cuna a la tumba. Por otro lado, la generación de la energía contribuye al impacto, debido a la utilización ... -
Experimental comparison of serpentine and parallel-tubes flat plate collectors for different flow rates
Comparación experimental del comportamiento térmico de dos captadores solares térmicos, uno serpentín y otro parrilla. In the paper, two flat plate solar collectors were simultaneously tested in a side-by-side facility ... -
Identificación de errores conceptuales comunes en estudiantes de Termodinámica Básica
Domínguez-Muñoz, Fernando; Serrano-Casares, Francisco Víctor
; Rodríguez-García, Eduardo Amador
; Guerra Macho, José J.; Lillo Bravo, Isidoro; Carrillo-Andrés, Antonio
; Cejudo-López, José Manuel
; Fernández-Hernández, Francisco Ángel
[et al.] (2015-06-26)
Se investigan los preconceptos sobre calor y temperatura que tienen los alumnos de ingeniería antes de recibir formación en Termodinámica. El diagnóstico se realiza mediante un cuestionario, pasado a principios de curso. ... -
Incertidumbres en la Simulación Energética de Edificios. Aplicación a la Rehabilitación Sostenible
Calleja Rodríguez, Gloria (Servicio de Publicaciones y Divulgación Científica, 2015)Los edificios antiguos ofrecen un elevado potencial de ahorro de energía porque son muy numerosos y porque su comportamiento está lejos de ser eficiente. Por ello, la rehabilitación de edificios es uno de los sectores ... -
Modelado de sistemas de desecantes sólidos para el tratamiento de aire de ventilación en edificios
Fernández-Hernández, Francisco Ángel(Servicio de Publicaciones y Divulgación Científica, 2015)
Se realiza un análisis de los sistemas de tratamiento de aire exterior de ventilación en edificios con desecantes sólidos. En edificios con elevadas ganancias internas y situados en ciudades con climas húmedos, los sistemas ...