- RIUMA Principal
- Listar por autor
Listar por autor "Postigo-Pozo, Sergio"
Mostrando ítems 1-19 de 19
-
3D kinematic mandible model to design mandibular advancement devices for the treatment of obstructive sleep apnea
García Reyes, Marcos; Cabrera Castillo, Juan A.; Bataller-Torras, Alex; Postigo-Pozo, Sergio
; Castillo-Aguilar, Juan Jesús
(Springer, 2020-11-05)
Mandibular advancement devices (MADs) are one of the treatments used for Obstructive sleep apnea (OSA). MADs try to maintain the mandible in an advanced position to keep the upper airways open when sleeping. To achieve ... -
A procedure for validating rigid catenary models using evolutionary techniques
Simarro-Vega, Montserrat; Postigo-Pozo, Sergio
; Cabrera-Carrillo, Juan Antonio
; Castillo-Aguilar, Juan Jesús
(Elsevier, 2020)
This paper describes a method to validate rigid catenary finite element models from modal tests. The model parameters are obtained by means of an optimization process using evolutionary techniques. The validation of rigid ... -
Analysis of contact forces between the pantograph and the overhead conductor rail using a validated finite element model
Simarro-Vega, Montserrat; Postigo-Pozo, Sergio
; Prado-Novoa, María
; Pérez-de-la-Blanca-Cobos, Ana María
; Castillo-Aguilar, Juan Jesús
(Elsevier, 2020)
This work presents the study of the interaction between 11 models of pantographs and 2 models of overhead conductor rails (OCR). All the models have been analysed at speeds of 70, 100 and 130 km/h. Furthermore, one of the ... -
Aplicación de la metodología basada en Design Thinking para el aprendizaje de conceptos técnicos ferroviarios
Castillo-Orihuela, Concepción; Postigo-Pozo, Sergio
; Ruiz-Mora, Isabel María
; Casanueva, Carlos; Abramovic, Borna; Marinov, Marin[et al.] (2022-11)
Docentes e investigadores de las áreas de Ingeniería Mecánica y de Comunicación Audiovisual de la Universidad de Málaga participan en un proyecto Europeo Eramus+ denominado ASTONRail. Dentro de las actividades desarrolladas ... -
Biomímesis Málaga: Plataforma de aprendizaje significativo e innovación inspirada en la naturaleza.
Álvarez-Nobell, Alejandro; Ruiz-Mora, Isabel María
; Barroso, María-Belén; Castillo-Aguilar, Juan Jesús
; Martín-Jaime, Juan Jesús
; Postigo-Pozo, Sergio
; Pérez-Ordóñez, Cristina de los Ángeles
; Castro-Martínez, Andrea
; López Gómez, Sara; Lawrence, Body[et al.] (Universidad de Málaga, 2023)
Plataforma del GIE – Grupo de Innovación Educativa “Biomímesis Málaga: Aprendizaje significativo e innovación inspirada en la naturaleza. -
Diseño de un dispositivo intraoral para el tratamiento de la apnea obstructiva del sueño con levas optimizadas para adaptarse a la cinemática de la mandíbula del paciente mediante algoritmos evolutivos
Bataller-Torras, Alex; Cabrera-Carrillo, Juan Antonio
; Nadal-Martínez, Fernando
; Postigo-Pozo, Sergio
(XV Congreso Iberoamericano de Ingeniería Mecánica, 2022)
Los Dispositivos de Avance Mandibular (DAM) han demostrado ser efectivos en el tratamiento de la Apnea Obstructiva del Sueño (AOS). Estos dispositivos abren las vías aéreas superiores manteniendo la mandíbula en una posición ... -
Dispositivo acoplable a servomotor para la rehabilitación de la articulación de la rodilla
Moya Esteban, Alejandro (2017-01-11)El objetivo de este Trabajo de Fin de Grado consiste en el desarrollo de un dispositivo mecánico, el cual gracias a un servomotor, sea capaz de realizar la movilización pasiva de la articulación de la rodilla en procesos ... -
Evaluation of the influence of the speed, preload and span length on the contact forces in the interaction between the pantograph and the overhead conductor rail
Simarro-Vega, Montserrat; Castillo-Aguilar, Juan Jesús
; Cabrera-Carrillo, Juan Antonio
; Postigo-Pozo, Sergio
(Elsevier, 2021)
The Overhead Conductor Rail is one of the methods to transmit energy to a moving train. This power feeding system has some advantages compared to the conventional overhead catenary system. However, its use is still mainly ... -
Influence of main operating conditions on contact wire wear of rigid catenary lines
Simarro, Monserrat; Postigo-Pozo, Sergio; Casanueva, Carlos; Rodriguez-Tembleque, Luis; Castillo-Aguilar, Juan Jesús
(Elsevier, 2024-08)
A validated overhead conductor rail and a well-known wear model have been programmed to perform closer-to- reality simulations. Reliable wear rate estimates for two configurations of overhead conductor rails and three models ... -
Is there a mechanical regulation of bone formation in spinal fusion?
Checa, Sara; Postigo-Pozo, Sergio; Rohlmann, Antonius; Putzier, Michael; Duda, Georg; Schmidt, Hendrik[et al.] (2013)
Introduction Lumbar interbody fusion using cages is one of the most reliable treatment options for degenerative spinal diseases. Currently, many cage designs are available in the market; however none of them is completely ... -
Kinematics of mandibular advancement devices (MADs): Why do some MADs move the lower jaw backward during mouth opening?
Cabrera-Carrillo, Juan Antonio; Bataller-Torras, Alex
; Postigo-Pozo, Sergio
; García Reyes, Marcos (Springer, 2024)
Mandibular advancement devices (MADs) are widely used treatments for obstructive sleep apnea. MADs function by advancing the lower jaw to open the upper airway. To increase patient comfort, most patients allow the mouth ... -
L4 fixation is not necessary in L5-Iliac spinopelvic fixation after trauma, but coadjutant transilio-transsacral fixation is
Sevillano-Pérez, Enrique; Prado-Novoa, María; Postigo-Pozo, Sergio
; Peña Trabalón, Alejandro; Guerado-Parra, Enrique
(Elsevier, 2024-01-24)
Spinopelvic dissociation (SPD) is a severe injury characterized by a discontinuity between the spine and the bony pelvis consisting of a bilateral longitudinal sacral fracture, most of the times through sacral neuroforamen, ... -
L4 fixation is not necessary in L5-Iliac spinopelvic fixation after trauma, but coadjutant transilio-transsacral fixation is
Sevillano-Pérez, Enrique; Prado-Novoa, María; Postigo-Pozo, Sergio
; Peña Trabalón, Alejandro; Guerado-Parra, Enrique
(Elsevier, 2024-03)
Introduction: Spinopelvic dissociation (SPD) is a severe injury characterized by a discontinuity between the spine and the bony pelvis consisting of a bilateral longitudinal sacral fracture, most of the times through sacral ... -
Medida de deformación mediante correlación de imágenes en 3D para caracterización biomecánica en hemimandíbulas de conejo
González Rueda, Jaime; Postigo-Pozo, Sergio; Prado-Novoa, María
(2016-11-25)
En el presente trabajo se estudia la viabilidad de una técnica de medición de deformaciones mediante correlación de imágenes sobre hemimandíbulas de conejo común de granja. Tanto la fisiología de la hemimandíbula como las ... -
Modelado con elementos finitos y actualización con ensayos modales experimentales de un cantón de catenaria rígida
Simarro-Vega, Montserrat; Postigo-Pozo, Sergio
; Almenara, Luis Fernando; Ania, Marcos; Simón-Mata, Antonio
(2017-11-03)
La catenaria rígida, comúnmente instalada en metropolitanos subterráneos, presenta ciertas ventajas respecto a otros sistemas convencionales de alimentación eléctrica en el transporte ferroviario, como es la catenaria ... -
Modelado de la interacción entre pantógrafo y catenaria rígida con técnicas de elementos finitos y validación con ensayos modales experimentales
Simarro-Vega, Montserrat(UMA Editorial, 2023)
El trabajo de la presente tesis se enmarca en el sector ferroviario. Desde su invención, el ferrocarril trajo cambios importantes en las costumbres de las sociedades. A día de hoy, el ferrocarril tiene además un papel ... -
Nueva técnica de fijación invertida para al LCA: estudio biomecánico in vitro en modelo porcino
Prado-Novoa, María; Pérez-Blanca-Cobos, Ana; Ezquerro-Juanco, Francisco
; Postigo-Pozo, Sergio
; García-Vacas, Francisco
; Espejo-Reina, Alejandro; Espejo-Baena, Alejandro[et al.] (2016-11-25)
Este trabajo analiza las propiedades mecánicas iniciales de una nueva técnica de reconstrucción del ligamento cruzado anterior (LCA) que invierte los elementos de fijación de la técnica estándar entre los sitios anatómicos, ... -
Presurgical 3D gait analysis findings in four children with spastic cerebral palsy
Smith-Fernández, Víctor Manuel; Postigo-Pozo, Sergio
; Postigo, María José; Prado-Novoa, María
; Núñez, María José; Ros, Bienvenido; Fernández, Victoria[et al.] (2014-01-07)
Introduction: Children with spastic palsy present usually with an altered gait pattern. This pattern presents various superimposed alterations, due to spasticity and due to musculosqueletal deformities; some of them are ... -
Soporte de catenaria rígida del túnel Sol-Nuevos Ministerios: modelado con elementos finitos y actualización con ensayos modales experimentales
Simarro-Vega, Montserrat; Postigo-Pozo, Sergio
; Torrealba, David; Almenara, Luis Fernando; Ania, Marcos; Simón-Mata, Antonio
[et al.] (2016-11-23)
La catenaria rígida presenta ciertas ventajas respecto a otros sistemas más convencionales de alimentación eléctrica en el transporte ferroviario. La tendencia a incrementar las velocidades de funcionamiento, crean la ...